The ASHRAE Handbook is published in a series of four volumes, one of which is revised each year, ensuring that no volume is older than four years.
The Handbook can be purchased at the ASHRAE Bookstore by clicking on this link.
TC8.1 is responsible for this chapter in the ASHRAE REFRIGERATION Handbook:
Factory Dehydrating, Charging, and Testing
Proper dehydration, charging, and testing of packaged refrigeration systems and components (compressors, evaporators, and condensing coils) help ensure proper performance and extend the life of refrigeration systems. This chapter covers the methods used to perform these functions. It does not address criteria such as allowable moisture content, refrigerant quantity, and performance, which are specific to each machine.
TC 8.1 is responsible for these chapters in the ASHRAE HVAC SYSTEMS AND EQUIPMENT Handbook
Liquid Chilling
Liquid-chilling systems cool water, brine, or other secondary coolant for air conditioning or refrigeration. The system may be either factory-assembled and wired or shipped in sections for erection in the field. The most frequent application is water chilling for air conditioning, although brine cooling for low-temperature refrigeration and chilling fluids in industrial processes are also common. The basic components of a vapor-compression, liquid-chilling system include a compressor, liquid cooler (evaporator), con-denser, compressor drive, liquid-refrigerant expansion or flow-control device, and control center; it may also include a receiver, economizer, expansion turbine, and/or subcooler. In addition, auxiliary components may be used, such as a lubricant cooler, lubricant separator, lubricant-return device, purge unit, lubricant pump, refrigerant transfer unit, refrigerant vents, and/or additional control valves. For information on absorption equipment, see ASHRAE Handbook—Refrigeration.
Compressors
A compressor is one of the four essential components of the basic vapor compression refrigeration system; the others are the condenser, evaporator, and expansion device. The compressor circulates refrigerant through the system and increases refrigerant vapor pressure to create the pressure differential between the condenser and evaporator. This chapter describes the design features of several categories of commercially available refrigerant compressors.
Comment on the Handbook: ASHRAE welcomes your comments on the Handbook or a specific Handbook chapter.
To submit a comment about any aspect or part of the Handbook series, you can use the Handbook Comment Form.
Review a Handbook Chapter: To provide your feedback about a specific Handbook chapter, you can answer the brief survey questions on the Handbook Chapter Review Form.